Pediatric Disposable Resuscitator with Reservoir Bag
Product Description
Textured PVC bag for sure grip and comfort. Clear, flexible PVC cushion face mask ensures tight seal. Non-rebreathing valve directs exhaled gas away from care giver. Includes medication/manometer port for use with MDI or syringe, an integrated PEEP connection, and a swivel patient connection. Collapsible. Latex-free. Meets ASTM and ISO standards.
Related products
-
Torso – Light
Product Description
CPARLENE® is flexible and adaptable; it was designed with modular components that require no conversion kits. Individual student face masks provide maximum protection from cross contamination. The disposable face mask is designed with a one-way non-rebreathing valve. Molded hair requires no maintenance. Disposable tracheal airway and lower airway with lung bag eliminates time consuming disinfection procedures. Every CPARLENE® manikin carries the Life/form®
Quality Features of CPARLENE®:
• Available in light or dark (torso only)
• Fully articulated head, neck, and jaw
• Non-rebreathing Airway System
• Sanitary Molded Hair
• Adult and Child CPR versions
• Life/form®CPR Training Capabilities with CPARLENE®:
• Jaw Thrust
• Pliable abdomen for obstructed airway procedure
• Manual Carotid Pulse
• Xiphoid, navel, nipples, and ribcage land marks
• Constricted and Dilated Eye
• Electronic Monitoring OptionsBasic CPARLENE® Torso includes basic adult torso, short sleeve jacket, sanitary face mask, disposable lower airway, disposable tracheal airway, and white fitting.
-
Code Simulator 12-Lead Arrhythmia Simulator – Phillips
Product Description
Pace and defibrillate directly into this interactive 12-lead ECG simulator through your hands-free defibrillation cable.
• Simulate electrical capture with your external pacer. Press simulator capture key to select one of four pre-set pacing capture levels: 70, 80, 90, or 100mA. When pacer current is greater than selected capture level, paced beats appear on your monitor. Waveforms for pacing include: Sinus Brady (two), 1st degree A-V block, 2nd degree type I A-V block, 2nd degree type II A-V block, 2nd degree type II A-V block with PVCs, and 3rd degree A-V block.
• Simulate cardioversion with your manual, semi-automatic, or automatic defibrillator. Activate “convert” feature to select – before defib discharge – another rhythm to run immediately after defib discharge. Waveforms for defibrillator training include: V. Fib., V. Tach (high rate), V. Tach (low rate), Torsade, A. Fib, A. Flutter, PSVT, Sinus Tach, Sinus Rhythm, Sinus Rhythm with PVCs, Asystole, and NSR.
• Generate realistic 12-lead ECG rhythms. Connect your ECG cable to simulator’s 10 ECG snaps. Independent chest lead and limb lead ECG signals create realistic 12-lead ECGs for each rhythm. Generate ST segment and T wave abnormalities including: Anterior MI, Inferior MI, Antero-Septal ST Elevation, Anterior ST Depression, Lateral ST Elevation, and Inferior ST Elevation.
• LED indicators: pacer pulse detection, defib discharge detection, and low battery. -
Code Simulator 12-Lead Arrhythmia Simulator – ZOLL
Pace and defibrillate directly into this interactive 12-lead ECG simulator through your hands-free defibrillation cable. Connects directly to monitor • Does not work with manikin • Simulate electrical capture with your external pacer. Press simulator capture key to select one of four preset pacing capture levels: 70, 80, 90, or 100mA. When pacer current is greater than selected capture level, paced beats appear on your monitor. Waveforms for pacing include: Sinus Brady (two), 1st degree A-V block, 2nd degree type I A-V block, 2nd degree type II A-V block, 2nd degree type II A-V block with PVCs, and 3rd degree A-V block. • Simulate cardioversion with your manual, semi-automatic, or automatic defibrillator. Activate “convert” feature to select - before defib discharge - another rhythm to run immediately after defib discharge. Waveforms for defibrillator training include: V. Fib., V. Tach (high rate), V. Tach (low rate), Torsade, A. Fib, A. Flutter, PSVT, Sinus Tach, Sinus Rhythm, Sinus Rhythm with PVCs, Asystole, and NSR. • Generate realistic 12-lead ECG rhythms. Connect your ECG cable to simulator’s 10 ECG snaps. Independent chest lead and limb lead ECG signals create realistic 12-lead ECGs for each rhythm. Generate ST segment and T wave abnormalities including: Anterior MI, Inferior MI, Antero-Septal ST Elevation, Anterior ST Depression, Lateral ST Elevation, and Inferior ST Elevation. • LED indicators: pacer pulse detection, defib discharge detection, and low battery.


Reviews
There are no reviews yet.